Service Parts Disassembly

REP 15.4 Transparency Sensor

PL15.2.7
8-176
1. Remove the Regi Transport Assembly (REP 15.2,
2. Disconnect the wiring harness connectors that are connected to the 2 sensors
and remove the harness from the Harness Guide.
3. Remove 2 screws (silver, Tapped, 8mm) that secure the Inlet Chute Assembly
and remove the Inlet Chute Assembly.
4. Remove the Sensor Holder.
5. Release the 4 hooks that secure the Transparency Sensor and remove the
Transparency Sensor.
page
8-174).
s7500-238
s7500-239