Lph Power Fail C - Xerox Phaser 7500 Service Manual

Hide thumbs Also See for Phaser 7500:
Table of Contents

Advertisement

LPH Power Fail C

Phaser 7500 Printer Service Manual
Fuse open circuit detection error during the LPH batch download complete
verification, or power system error.
When the LPH Power On Fail occurs in the LPH of every color (Y, M, C, K), it is a Fuse
open circuit detection error. When the LPH Power On Fail occurs in the LPH of 1
color, it is a power system error because there is a high chance that the error lies
with the power supply connector.
Note
If this error occurs, it is possible that the process have not been performed
correctly because of other LPH Fail. If other LPH Fail had occurred, solving that
other LPH Fail has a higher priority.
Applicable Chain-Link Code
061-352: LPH Power On Fail C
Initial Actions
Power cycle the printer.
If the problem persists, follow the procedure below.
Troubleshooting Reference
Applicable Parts
LPH Unit (C), PL2.1.2
LPH Cable Assy, PL2.2.1
LPH Rear PWB (C), PL2.2.5
MCU PWB, PL18.3.6
Motor Drive PWB, PL18.3.7
Troubleshooting Procedure
Step
Actions and Questions
1
Check the Fault History.
Have multiple errors occurred?
Error Messages and Codes
Wiring and Plug/Jack Map References
Yes
Go to step 3.
No
Go to step 2.