Motor Drive PWB F1 Blows

Phaser 7500 Printer Service Manual
Fuse 1 on the Motor Drive PWB has blown.
Note
Remove the cause of Fuse failure before replacing the Motor Drive PWB.
Applicable Chain-Link Code
041-344: PWBA Motor Drive F1 Fuse Break Fail
Initial Actions
Power cycle the printer.
If the problem persists, follow the procedure below.
Troubleshooting Reference
Applicable Parts
Fuser Fan, PL4.1.7
Regi Clutch, PL15.2.4
Fuse
1. Check the following parts circuits for overcurrent and overvoltage, grounded
wires, and then replace the faulty parts or repair the circuits, and replace the
Fuse.
Regi Clutch (REP 15.3,
Fuser Fan (REP 4.1,
Wiring and Plug/Jack Map References
page
8-175)
page
8-38)