Error Messages and Codes
MCU PWB F7 Blows
Applicable Chain-Link Code
Initial Actions
3-98
Fuse 7 on the MCU PWB has opened.
Note
Remove the cause of Fuse failure before replacing the MCU PWB.
•
041-330: PWBA MCU F7 Fuse Break Fail
•
Power cycle the printer.
•
If the problem persists, follow the procedure below.
Troubleshooting Reference
Applicable Parts
1st BTR Contact Retract
■
Clutch, PL3.2.12
HV Fan, PL4.3.4
■
Takeaway Clutch, PL15.1.1
■
MCU PWB, PL18.3.6
■
Drive Fan, PL18.3.17
■
Fuse
■
1. Check the following parts circuits for over current and overvoltage, grounded
wires, and then replace the faulty parts or repair the circuits, and replace the
Fuse.
•
Drive Fan (REP 18.15,
•
HV Fan (REP 4.3,
page
•
1st BTR Contact Retract Clutch
•
Takeaway Clutch (REP 15, 1,
2. Replace the MCU PWB (REP 18.12,
Wiring and Plug/Jack Map References
page
8-206)
8-40)
page
8-172)
page
8-202).
Phaser 7500 Printer Service Manual