Error Messages and Codes
3-112
Troubleshooting Procedure (Continued)
Step
Actions and Questions
4
Check the connections between
the Motor Drive PWB J508 and the
Drum/ Deve Drive Motor (K) J240,
as well as between the Motor Drive
PWB J506 and the Drum/ Deve
Drive Motor (K) J241 for open
circuits, short circuits, and poor
contacts.
Are they conducting properly?
5
Install the Imaging Unit (K) and
the Developer (K) and close the
Front Cover.
Perform the Developer Motors test
in Diagnostics.
Does the Drum/ Deve Drive Motor
(K) rotate?
6
Check the connection between the
Drum/Deve Drive Motor (K) J241-8
and the Motor Drive PWB J506-1
for open circuit, short circuit, and
poor contact.
Is it conducting properly?
Yes
No
Replace the
Repair the
following parts
sections that
in sequence:
have short
circuits and
Drum/Deve
■
Drive Motor
poor contacts.
(K) (REP 3.9,
page
8-35)
Motor Drive
■
PWB (REP
18.13,
page
8-204)
MCU PWB
■
(REP 18.12,
page
8-202)
Go to step 6.
Check the
Imaging Unit
(K) and the
Developer (K) for
loading.
Replace the
Repair the
following parts
sections that
in sequence:
have short
circuits and
Motor Drive
■
PWB (REP
poor contacts.
18.13,
page
8-204)
MCU PWB
■
(REP 18.12,
page
8-202)
Phaser 7500 Printer Service Manual