H3: Analog Inputs - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

10 Parameter List
Setting
Function
4F
Braking Resistor
Overheat (rH)
51
Safe Torque OFF
52
Warning Signal
60
Internal Cooling
Fan Failure
62
Modbus Reg 1
Status Satisfied
63
Modbus Reg 2
Status Satisfied
66
Comparator1
67
Comparator2
69
External Power
24V Supply
6A
Data Logger Error
B1
DC Injection
Braking at Start
B2
DC Injection
Braking at Stop
B3
Motor 3 Selection
100 to 1FF Inverse Output of 0
to FF

H3: Analog Inputs

No.
Name
(Hex.)
H3-01
Terminal A1 Signal
Level Select
(0410)
H3-02
Terminal A1
Function Selection
(0434)
468
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the braking resistor overheats and the drive detects an rH
[Braking Resistor Overheat] fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on (safety stop state) when the safety circuit and safety diagnosis
circuit is not experiencing a failure and when both terminals H1-HC and H2-HC are off
(released).
ON : Safety stop state
OFF : Safety circuit fault or RUN/READY
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the number of starts reaches the detection level.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects a cooling fan failure in the drive.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the bit specified by H2-08 [Modbus Register 1 Bit Select]
for the MEMOBUS register address set with H2-07 [Modbus Register 1 Address Select]
activates.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the bit specified by H2-10 [Modbus Register 2 Bit Select]
for the MEMOBUS register address set with H2-09 [Modbus Register 2 Address Select]
activates.
V/f
CL-V/f
OLV
CLV
AOLV
The monitor value set with H2-20 [Comparator 1 Monitor Selection] is on while in range
of the time set with H2-24 [Comparator 1 On-Delay Time] and the values of H2-21
[Comparator 1 Lower Limit] and H2-22 [Comparator 1 Upper Limit] are in range.
V/f
CL-V/f
OLV
CLV
AOLV
The monitor value set with H2-26 [Comparator 2 Monitor Selection] is on while in range
of the time set with H2-30 [Comparator 2 On-Delay Time] and the values of H2-27
[Comparator 2 Lower Limit] and H2-28 [Comparator 2 Upper Limit] are in range.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when there is an external 24V power supply between terminals
PS-AC.
ON : An external 24V power supply supplies power.
OFF : An external 24V power supply does not supply power.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects a LoG [Com Error / Abnormal SD card].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the motor is started and during DC Injection Braking.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the motor is stopped and during DC Injection Braking.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when motor 3 is selected.
ON : Motor 3 Selection
OFF : Motor 1 or Motor 2 Selection
V/f
CL-V/f
OLV
CLV
AOLV
Generates inverse output of the function for the selected MFDO. Sets the function for
which to generate inverse output with the last two digits of 1xx.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input signal level for MFAI terminal A1.
0 : 0 to 10 V (Lower Limit at 0)
1 : -10 to +10V (Bipolar Reference)
V/f
CL-V/f
OLV
CLV
AOLV
Selects a function assigned to the MFAI terminal A1.
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
Ref.
680
680
680
199
203
680
680
680
680
681
681
681
682
682
682
193
203
682
Default
(Range)
0
(0, 1)
0
(0 - FF)

Advertisement