E3: V/F Pattern For Motor 2 - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

No.
Name
(Hex.)
E2-06
Motor Leakage
Inductance
(0313)
E2-07
Motor Saturation
Coefficient 1
(0314)
E2-08
Motor Saturation
Coefficient 2
(0315)
E2-09
Motor Mechanical
Loss
(0316)
Expert
E2-10
Motor Iron Loss
(0317)
E2-11
Motor Rated Power
(kW)
(0318)

E3: V/f Pattern for Motor 2

No.
Name
(Hex.)
E3-01
Motor 2 Control
Mode Selection
(0319)
E3-04
Motor 2 Maximum
Output Frequency
(031A)
E3-05
Motor 2 Maximum
Output Voltage
(031B)
E3-06
Motor 2 Base
Frequency
(031C)
E3-07
Motor 2 Mid Point A
Frequency
(031D)
E3-08
Motor 2 Mid Point A
Voltage
(031E)
E3-09
Motor 2 Minimum
Output Frequency
(031F)
E3-10
Motor 2 Minimum
Output Voltage
(0320)
E3-11
Motor 2 Mid Point B
Frequency
(0345)
Expert
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage drop due to motor leakage inductance as a
percentage of motor rated voltage while the motor is operating at the
rated frequency and rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Set the motor iron-core saturation coefficient when the magnetic
flux is 50%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron-core saturation coefficient at 75% of the
magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mechanical loss of the motor. Motor rated power (kw) =
100.0%. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron loss in watts.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated power in 0.01 kW. (1 HP = 0.746 kW)
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the control method for motor 2.
0 : V/f Control
1 : Closed Loop V/f control
2 : Open Loop Vector
3 : Closed Loop Vector
V/f
CL-V/f
OLV
CLV
AOLV
Set the maximum output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage used for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern. Set this
parameter to adjust the V/f pattern for the constant output range. Usually it
is not necessary to change this setting.
10 Parameter List
Default
Ref.
(Range)
Determined by o2-
599
04
(0.0 - 60.0%)
0.50
599
(0.00 - 0.50)
0.75
599
(E2-07 - 0.75)
0.0%
599
(0.0 - 10.0%)
Determined by o2-
600
04
(0 - 65535 W)
Determined by o2-
600
04
(0.00 - 650.00 kW)
Default
(Range)
2
(0 - 3)
Determined by E3-01
(40.0 - 590.0 Hz)
Determined by E3-01
(200 V Class: 0.0 -
255.0 V,
400 V Class: 0.0 -
510.0 V)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(200 V Class: 0.0 -
255.0 V,
400 V Class: 0.0 -
510.0 V)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(200 V Class: 0.0 -
255.0 V,
400 V Class: 0.0 -
510.0 V)
0.0 Hz
(0.0 - E3-04)
443