E: Motor Parameters; E1: V/F Pattern For Motor 1 - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

E: Motor Parameters

E1: V/f Pattern for Motor 1

No.
Name
(Hex.)
E1-01
Input AC Supply
Voltage
(0300)
E1-03
V/f Pattern Selection
(0302)
E1-04
Maximum Output
Frequency
(0303)
E1-05
Maximum Output
Voltage
(0304)
E1-06
Base Frequency
(0305)
E1-07
Mid Point A
Frequency
(0306)
E1-08
Mid Point A Voltage
(0307)
E1-09
Minimum Output
Frequency
(0308)
E1-10
Minimum Output
Voltage
(0309)
E1-11
Mid Point B
Frequency
(030A)
Expert
E1-12
Mid Point B Voltage
(030B)
Expert
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive input voltage to match the power supply voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the V/f pattern for the drive and motor from 15 predefined patterns
(settings: 0 to E) or creates a custom V/f pattern(setting: F).
0 : Const Trq, 50Hz base, 50Hz max
1 : Const Trq, 60Hz base, 60Hz max
2 : Const Trq, 50Hz base, 60Hz max
3 : Const Trq, 60Hz base, 72Hz max
4 : VT, 50Hz, 65% Vmid reduction
5 : VT, 50Hz, 50% Vmid reduction
6 : VT, 60Hz, 65% Vmid reduction
7 : VT, 60Hz, 50% Vmid reduction
8 : High Trq, 50Hz, 25% Vmin boost
9 : High Trq, 50Hz, 65% Vmin boost
A : High Trq, 60Hz, 25% Vmin boost
B : High Trq, 60Hz, 65% Vmin boost
C : High Freq, 60Hz base, 90Hz max
D : High Freq, 60Hz base, 120 Hz max
E : High Freq, 60Hz base, 180 Hz max
F : Custom
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the middle output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle point voltage for the V/f pattern.
10 Parameter List
Default
(Range)
200 V Class: 200 V,
400 V Class: 400 V
(200 V Class: 155 -
255 V, 400 V Class:
310 - 510 V)
F
(Determined by A1-
02)
Determined by A1-02
(Determined by A1-
02)
Determined by A1-02
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Determined by A1-02
(0.0 to E1-04)
Determined by A1-02
(0.0 - E1-04)
Determined by A1-02
(200 V Class: 0.0 -
255.0 V,
400 V Class: 0.0 -
510.0 V)
Determined by A1-02
(Determined by A1-
02 and E1-04)
Determined by A1-02
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
0.0 Hz
(0.0 - E1-04)
0.0 V
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)