Replace A Fan (Procedure D) - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

2.
Align the notches on the fan with the pin on the drive and install the cooling fan in the drive.
A - Notch on fan
B - Alignment pins on drive
Note:
When you install the cooling fan, make sure that you do not pinch cables between the cooling fan and the drive.
3.
Put the cable in the recess of the drive.
A - Front of drive
4.
Push the hooks on the left and right sides of the fan finger guard and click it into place on the drive.
5.
Energize the drive and set o4-03 = 0 [Fan Operation Time Setting = 0 h] to reset the cooling fan operation
time.

Replace a Fan (Procedure D)

WARNING
Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before
servicing, disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal
capacitor stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage
decreases below 50 Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make
sure that the drive is safe. Failure to obey will cause death or serious injury.
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
C - Front of drive
Figure 7.17 Install the Cooling Fan
Figure 7.18 Put the Cable in the Drive Recess
Figure 7.19 Reattach the Fan Finger Guard
7 Periodic Inspection and Maintenance