F4: Analog Monitor Option - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

No.
Name
(Hex.)
F3-17
Terminal D7
Function Selection
(0BEA)
Expert
F3-18
Terminal D8
Function Selection
(0BEB)
Expert
F3-19
Terminal D9
Function Selection
(0BEC)
Expert
F3-20
Terminal DA
Function Selection
(0BED)
Expert
F3-21
Terminal DB
Function Selection
(0BEE)
Expert
F3-22
Terminal DC
Function Selection
(0BEF)
Expert
F3-23
Terminal DD
Function Selection
(0BF0)
Expert
F3-24
Terminal DE
Function Selection
(0BF1)
Expert
F3-25
Terminal DF
Function Selection
(0BF2)
Expert

F4: Analog Monitor Option

No.
Name
(Hex.)
F4-01
Terminal V1
Function Selection
(0391)
F4-02
Terminal V1 Gain
(0392)
RUN
F4-03
Terminal V2
Function Selection
(0393)
F4-04
Terminal V2 Gain
(0394)
RUN
F4-05
Terminal V1 Bias
(0395)
RUN
F4-06
Terminal V2 Bias
(0396)
RUN
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D7 of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D8 of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D9 of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DA of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DB of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DC of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DD of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DE of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DF of the DI-A3 when F3-01 = 8 [Digital
Input Function Selection = Multi-Function Digital Input].
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor signal output from terminal V1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the monitor signal that is sent from terminal V1. Sets the
analog signal output level from the terminal V1 at 10 V or 20 mA as 100%
when an output for monitoring items is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number for monitor item of output from terminal V2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the monitor signal that is sent from terminal V2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the monitor signal that is sent from terminal V1. Set the
level of the analog signal sent from the V1 terminal at 10 V or 20 mA as
100% when an output for monitoring items is 0%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the monitor signal that is sent from terminal V2. Set the
level of the analog signal sent from the V2 terminal at 10 V or 20 mA as
100% when an output for monitoring items is 0%.
10 Parameter List
Default
(Range)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
F
(0 - 1FF)
Default
(Range)
102
(000 - 999)
100.0%
(-999.9 - +999.9%)
103
(000 - 999)
50.0%
(-999.9 - +999.9%)
0.0%
(-999.9 - +999.9%)
0.0%
(-999.9 - +999.9%)
449