2 : Fast Stop (Use C1-09)
The drive stops the motor using the deceleration time set in C1-09 [Fast Stop Time]. Fault relay output terminal
MA-MC will turn ON, and MB-MC will turn OFF.
3 : Alarm Only
CE appears on the keypad, and operation continues. The output terminal set for Alarm [H2-01 to H2-05 = 10]
switches ON.
H5-05: Comm Fault Detection Selection
No.
Name
(Hex.)
H5-05
Comm Fault
Detection Selection
(0429)
If the drive does not receive data from the master during the time set in H5-09 [CE Detection Time], it will detect
a CE error.
0 : Disabled
Does not detect CE. The drive continues operation.
1 : Enabled
Detects CE. If the drive detects CE, it will operate as specified by the setting of H5-04 [Communication Error
Stop Method].
H5-06: Drive Transmit Wait Time
No.
Name
(Hex.)
H5-06
Drive Transmit Wait
Time
(042A)
H5-09: CE Detection Time
No.
Name
(Hex.)
H5-09
CE Detection Time
(0435)
H5-10: Modbus Register 0025H Unit Sel
No.
Name
(Hex.)
H5-10
Modbus Register
0025H Unit Sel
(0436)
0 : 0.1 V units
1 : 1 V units
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that detects CE [Modbus Communication Error] issues
during MEMOBUS/Modbus communications.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to wait to send a response message after the drive receives a
command message from the master.
Figure 11.82 Drive Transmit Wait Time
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for CE [Modbus Communication Error] issues when
communication stops.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the unit of measure used for the MEMOBUS/Modbus communications
monitor register 0025H (output voltage reference monitor).
11 Parameter Details
Default
(Range)
1
(0, 1)
Default
(Range)
5 ms
(0 - 65 ms)
Default
(Range)
2.0 s
(0.0 - 10.0 s)
Default
(Range)
0
(0, 1)
697