Replace A Cooling Fan And Circulation Fan; Number Of Cooling Fans And Circulation Fans Used - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

7 Periodic Inspection and Maintenance
Display
Alarm Name
Cooling Fan
LT-1
Maintenance
Time
Capacitor
LT-2
Maintenance
Time
SoftChargeBy
LT-3
passRelay
MainteTime
IGBT
LT-4
Maintenance
Time (50%)
IGBT
TrPC
Maintenance
Time (90%)
Related Parameters
Replace the component, then set o4-03, o4-05, o4-07, and o4-09 [Maintenance Setting] = 0 to reset the
Maintenance Monitor. If these parameters are not reset after the corresponding parts have been replaced, the
Maintenance Monitor function will continue to count down the performance life from the value that was reached
with the old part. If the Maintenance Monitor is not reset, the drive will not have the correct value of the
performance life for the new component.
Note:
The drive installation environment has an effect on the maintenance period.
No.
Name
o4-03
Fan Operation Time Setting
o4-05
Capacitor Maintenance Setting
o4-07
Softcharge Relay Maintenance
Set
o4-09
IGBT Maintenance Setting

Replace a Cooling Fan and Circulation Fan

NOTICE
Follow cooling fan replacement instructions. Replace all fans when performing maintenance to help ensure
maximum useful product life. Improper fan replacement could cause damage the drive.
To replace a cooling fan or circulation fan, contact Yaskawa or your nearest sales representative.

Number of Cooling Fans and Circulation Fans Used

Table 7.11 Cooling Fans and Circulation Fans (Three-Phase 200 V)
Model
2003 to 2011
2014, 2018
2025, 2033
2047
362
Table 7.9 Maintenance Period Alarms
Cause
The cooling fan is at 90% of its
performance life estimate.
The main circuit and control circuit
capacitors are at 90% of their
performance life estimate.
The soft charge bypass relay is at
90% of its performance life estimate.
The IGBTs are at 50% of their
performance life estimate.
The IGBTs are at 90% of their
performance life estimate.
Table 7.10 Maintenance Setting Parameters
Sets the value from which to start the cumulative drive cooling fan operation time in
10-hour units.
Note:
When o4-03 = 30 has been set, the drive will count the operation time for the
cooling fan from 300 hours and U4-03 [Cooling Fan Ope Time] will show 300 h.
Sets the value from which to start the count for the main circuit capacitor
maintenance period as a percentage.
Sets as a percentage the value from which to start the count for the soft charge bypass
relay maintenance time.
Sets the value from which to start the count for the IGBT maintenance period as a
percentage.
Cooling Fan
-
1
2
2
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Solution
Replace the cooling fan, then set o4-03 = 0
[Fan Operation Time Setting = 0 h] to reset
the cooling fan operation time.
Replace the board or the drive.
Contact Yaskawa or your nearest sales
representative to replace the board.
Replace the board or the drive.
Contact Yaskawa or your nearest sales
representative to replace the board.
Check the load, carrier frequency, and output
frequency.
Replace the IGBTs or the drive.
Function
Circulation Fans
Replacement Procedure
-
-
-
-
MFDO
(Setting
Value in H2-
xx)
2F
10
-
Procedure A