O2: Keypad Operation - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

10 Parameter List
No.
Name
(Hex.)
o1-50
Trend Plot 2 Scale
Maximum Value
(11CA)
RUN
o1-51
Trend Plot Time
Scale Setting
(11CB)
RUN
o1-55
Analog Gauge
Area Selection
(11EE)
RUN
o1-56
Analog Gauge
Area Setting
(11EF)
RUN

o2: Keypad Operation

No.
Name
(Hex.)
o2-02
STOP Key
Function Selection
(0506)
o2-03
User Parameter
Default Value
(0507)
o2-04
Drive Model
(KVA) Selection
(0508)
o2-05
Home Mode Freq
Ref Entry Mode
(0509)
o2-06
Keypad Disconnect
Detection
(050A)
o2-07
Keypad RUN
Direction @
(0527)
Power-up
486
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the
monitor that was set in o1-25 [Custom Monitor 2] as a trend plot.
This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time scale (horizontal axis) to display the trend plot. When
you change this setting, the drive automatically adjusts the data
sampling time. This parameter is only available with an LCD
keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the range used when displaying the monitor set in o1-24 as an
analog meter. This parameter is only available when you use an
LCD keypads.
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value used to display the monitor set in o1-24 [Custom
Monitor 1] as an analog meter. This parameter is only available with
an LCD keypad.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to stop the drive with the
keypad when the Run command source for the drive is REMOTE
(external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to keep the settings of changed parameters as user
parameter defaults to use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Drive Model code for the corresponding Drive Model. This
parameter must be set when control boards are replaced.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that makes it necessary to push the
change the frequency reference value with the keypad when in
Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether or not to stop the drive when the keypad connection
cable is disconnected from the drive or damaged while the keypad is
the Run command source.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation when the drive is energized and
the keypad is the Run command source.
0 : Forward
1 : Reverse
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Default
(Range)
100.0%
(-99.9 - +300.0%)
300 s
(1 - 3600 s)
1
(0, 1)
100.0%
(0.0 - 100.0%)
Default
(Range)
1
(0, 1)
button on the
0
(0 - 2)
Determined by the
drive model
(-)
0
(0, 1)
button to
0
(0, 1)
0
(0, 1)
Ref.
745
745
745
745
Ref.
746
746
746
747
747
748

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr700

Table of Contents