B2: Dc Injection Braking; B4: Timer Function - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

10 Parameter List
No.
Name
(Hex.)
b1-23
Selection REV
Parameters
(0B1D)
b1-35
Digital Input
Deadband Time
(1117)
Expert

b2: DC Injection Braking

No.
Name
(Hex.)
b2-01
DC Injection/Zero
SpeedThreshold
(0189)
b2-02
DC Injection Braking
Current
(018A)
b2-03
DC Inject Braking
Time at Start
(018B)
b2-04
DC Inject Braking
Time at Stop
(018C)
b2-08
Magnetic Flux
Compensation Value Sets how much current the drive injects when DC Injection Braking at Start
(0190)

b4: Timer Function

No.
Name
(Hex.)
b4-03
Terminal M1-M2
ON-Delay Time
(0B30)
Expert
b4-04
Terminal M1-M2
OFF-Delay Time
(0B31)
Expert
b4-05
Terminal M3-M4
ON-Delay Time
(0B32)
Expert
b4-06
Terminal M3-M4
OFF-Delay Time
(0B33)
Expert
b4-07
Terminal M5-M6
ON-Delay Time
(0B34)
Expert
b4-08
Terminal M5-M6
OFF-Delay Time
(0B35)
Expert
b4-09
Terminal P1-C1 ON-
Delay Time
(0B36)
Expert
432
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the operation of reverse parameters.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the deadband time for MFDIs.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency at which DC Injection Braking and Zero Servo starts.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Injection Braking current as a percentage of the drive rated
current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Inject Braking Time at start. Sets the Zero Speed Control time
at start in CLV.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Inject Braking Time at stop. Sets the Zero Speed Control time
at stop in CLV.
V/f
CL-V/f
OLV
CLV
AOLV
starts (Initial Excitation) as a percentage of E2-03 [Motor No-Load
Current].
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to activate the contact after the function set in H2-01
activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to deactivate the contact after the function set in H2-01
deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to activate the contact after the function set in H2-02
activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to deactivate the contact after the function set in H2-02
deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time until the contact is turned on after the function set with
H2-03 turns on.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time until the contact is turned off after the function set with
H2-03 turns OFF.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time until the contact is turned ON after the function set with
H2-04 turns on.
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Default
(Range)
0
(0, 1)
0.0 ms
(0.0 to 100.0 ms)
Default
(Range)
0.5
(0.0 - 10.0 Hz)
50%
(0 - 100%)
0.00 s
(0.00 - 10.00 s)
Determined by A1-02
(0.00 - 10.00 s)
0%
(0 - 1000%)
Default
(Range)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)
0 ms
(0 - 65000 ms)