Error Codes - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

5 Network Communications
Minor
Fault
Code
(Hex.)
000D
EF7 [External Fault (Terminal S7)]
000E
EF8 [External Fault (Terminal S8)]
000F
FAn [Internal Fan Fault]
0010
oS [Overspeed]
0011
dEv [Speed Deviation]
0012
PGo [Encoder (PG) Feedback Loss]
0014
CE [Modbus Communication Error]
0015
bUS [Option Communication Error]
0016
CALL [Serial Comm Transmission Error]
0017
oL1 [Motor Overload]
0018
oL2 [Drive Overload]
001A
EF0 [Option Card External Fault]
001B
rUn [Motor Switch during Run]
001D
CALL [Serial Comm Transmission Error]
0020
SE [Modbus Test Mode Error]
0021
L24v [Loss of External Power 24 Supply]
0022
oH3 [Motor Overheat (PTC Input)]
0023
EF9 [External Fault (Terminal S9)]
0024
EF10 [External Fault (Terminal S10)]
002B
PGoH [Encoder (PG) Hardware Fault]
0031
E5 [MECHATROLINK Watchdog Timer Err]
0032
AEr [Station Address Setting Error]
0033
CyC [MECHATROLINK CommCycleSettingErr]

Error Codes

MEMOBUS/Modbus Communications Error Code List
The following table lists the MEMOBUS/Modbus communications error codes.
When an error occurs, remove the cause of the error and restart communications.
Table 5.15 MEMOBUS/Modbus Communications Error Codes
Error Code
Name
(Hex.)
01
Function Code Error
Register Number
02
Error
03
Bit Count Error
21
Data Setting Error
316
Name
The PLC set a function code that was not 03, 08, 10, 5A, or 67 (Hex.).
• The register number that is trying to access is not registered.
• A starting number that was not 0001 or 0002 (Hex.) was set when broadcasting.
• Read and write data quantities are more than the 1 to 16 range. (Command message data
quantity is disabled.)
• The data that was read from non-consecutive holding registers contained more than 120 bytes.
• The data to be written to non-consecutive holding registers contained more than 60 bytes.
• In the write mode, the number of bytes in the message is not the number of data × 2.
• Writing control data or parameters made the settings go out of the permitted setting range.
• A parameter setting error occurred when writing a parameter.
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Minor
Fault
Name
Code
(Hex.)
0034
HCA [High Current Alarm]
0035
LT-1 [Cooling Fan Maintenance Time]
0036
LT-2 [Capacitor Maintenance Time]
0039
EF1 [External Fault (Terminal S1)]
003A
EF2 [External Fault (Terminal S2)]
003B
SToF [Safe Torque OFF Hardware]
003C
STo [Safe Torque OFF]
0042
TrPC [IGBT Maintenance Time (90%)]
0043
LT-3 [SoftChargeBypassRelay MainteTime]
0044
LT-4 [IGBT Maintenance Time (50%)]
0045
boL [Braking Transistor Overload]
0071
FWdL [Fwd Limit (FWdL)]
0072
rEvL [Rev Limit (rEvL)]
0073
oL3 [Overtorque Detection 1]
0074
oL4 [Overtorque Detection 2]
0075
oL5 [Overload Detection (oL5)]
0076
oL6 [Light-load Accel 2 Fault (oL6)]
0081
EP24v [External Power 24V Supply]
0085
bAT [Keypad Battery Low Voltage]
0087
CP1 [Comparator 1 Limit Error]
0088
CP2 [Comparator 2 Limit Error]
0089
TiM [Keypad Time Not Set]
008A
bCE [Bluetooth Communication Error]
Cause

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr700

Table of Contents