DANGER
Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before
servicing, disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal
capacitor stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage
decreases below 50 Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make
sure that the drive is safe. Failure to obey will cause death or serious injury.
The procedure for wiring the main circuit terminal block differs depending on the drive model. Refer to Table
2.12 for details.
Table 2.12 Types of Wiring Procedure for the Main Circuit Terminal Block
Model
2003 - 2180
4002 - 4150
2215 - 2415
4180 - 4605
Wiring Procedure for the Main Circuit Terminal Block
DANGER
Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before
servicing, disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal
capacitor stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage
decreases below 50 Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make
sure that the drive is safe. Failure to obey will cause death or serious injury.
The procedure for wiring the main circuit terminal block differs depending on the drive model. Refer to Table
2.13 for details.
Table 2.13 Types of Wiring Procedure for the Main Circuit Terminal Block
Model
2003 - 2180
4002 - 4150
2215 - 2415
4180 - 4605
Wiring the Main Circuit Terminal Block Using Procedure A
Wire the main circuit terminal block correctly as specified by the instructions in the manual.
Read these instructions before wiring the terminal block.
80
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Procedure
Procedure A
Procedure B
Procedure
Procedure A
Procedure B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr700

Table of Contents