Change The Drive Enclosure Type; Attach The Protective Cover (Procedure A) - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

Change the Drive Enclosure Type

The enclosure type of the drive is the open chassis type (IP20). The following explains how to change the
enclosure type to the enclosed wall-mounted type (UL Type 1). The procedure for installing UL Type 1 protective
covers is explained.
Install the protective covers before wiring the drive.
The procedure for installing the protective covers differs depending on the drive model. Refer to Table 2.8 for
details.
Table 2.8 Procedure for Installing UL Type 1 Protective Covers
Model
2003 to 2075
4002 to 4045
2088
4060
2115
4075 to 4091
2145 to 2180
4112 to 4150
2215 to 2283
4180 to 4260
2346
4304

Attach the Protective Cover (Procedure A)

Attach the Top Protective Cover
Align the hooks on the rear of top protective cover with the holes on the top of the drive to attach the top
protective cover.
Note:
• Attach the top protective cover and point the ( ) mark on the upper surface of the top protective cover away from the front of the
drive.
• Put the two small hooks on the rear of the top protective cover into the mounting holes near the back of the drive. Then push down on
the front side of the top protective cover to attach the cover.
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Figure 2.32 Reattach the Terminal Cover
2 Mechanical & Electrical Installation
Procedure
Procedure A
Procedure B
Procedure C
Procedure D
Procedure E
Procedure F
39