N2: Auto Freq Regulator (Afr); N3: Overexcitation Braking - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

No.
Name
(Hex.)
n1-16
Hunting Prevention
High Fc Gain
(0BFB)
n1-17
Hunting Prevent High
Fc Filter
(0BFC)
Expert
n1-20
Voltage Calibration
Duration
(1588)
Expert

n2: Auto Freq Regulator (AFR)

No.
Name
(Hex.)
n2-01
Automatic Freq
Regulator Gain(F)
(0584)
n2-02
Automatic Freq
Regulator Time 1
(0585)
n2-03
Automatic Freq
Regulator Time 2
(0586)
n2-06
Automatic Freq
Regulator Gain(R)
(1567)

n3: Overexcitation Braking

No.
Name
(Hex.)
n3-13
OverexcitationBrak
ing (OEB) Gain
(0531)
n3-14
OEB High Frequency
Injection
(0532)
Expert
n3-21
HSB Current
Suppression Level
(0579)
n3-23
Overexcitation
Braking Operation
(057B)
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the hunting prevention function. This parameter functions
best with a high carrier frequency. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the hunting prevention function. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time for voltage detection circuit calibration during startup. Usually
it is not necessary to change this setting.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the AFR function for forward run as a magnification value.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant that sets the rate of change for the AFR function.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant to determine the variation in speed of the AFR
function. Use this parameter during regeneration. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the AFR function for reverse run as a magnification value.
Usually it is not necessary to change this setting.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain value that the drive multiplies by the V/f pattern output value
during overexcitation deceleration to calculate the overexcitation level.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that injects harmonic signals during overexcitation
deceleration.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit of the current that is suppressed at the time of
overexcitation deceleration, where the drive rated current = 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation where the drive will enable
overexcitation.
0 : Disabled
1 : Enabled Only when Rotating FWD
2 : Enabled Only when Rotating REV
10 Parameter List
Default
(Range)
Determined by o2-04
(0.00 - 2.50)
500 ms
(0 - 1000 ms)
50 ms
(10 - 500 ms)
Default
(Range)
1.00
(0.00 - 10.00)
50 ms
(0 - 2000 ms)
750 ms
(0 - 2000 ms)
1.00
(0.00 - 10.00)
Default
(Range)
1.10
(1.00 - 1.40)
0
(0, 1)
100%
(0 - 150%)
0
(0 - 2)
481