LAMP(Alarm Light) Installation (J14, Molex 2P)
■ Signal of Pin and Connection
■ Connector Pin No.
■ Direct Connection with Alarm Light
BUZZER Installation (J13, Molex 2P)
■ Connector Pin No.
■ Direct connection BUZZER (DC 24V)
162 NEXIA-SY Series User Manual
LAMP Signal
Pin No.
Connector J14
1
2
2
-24V DC Type
+
1
Pin
BUZZER Signal
Connector J13
N
1
2
BUZZER
2
1
2
-24V DC Type
+ Buzzer
1
+24V
LAMP
2
1
Alarm
+24V