Wilo Yonos GIGA2.0-I Installation And Operating Instructions Manual page 205

Table of Contents

Advertisement

Available languages

Available languages

18.2.4
Module fan replacement
Fig. 102: Open the cover of the electronic
module
Fig. 103: Loosen the connection cable of the
module fan
Installation and operating instructions Wilo-Yonos GIGA2.0-I/-D
Maintenance
4.
Press the electronic module into the new motor contacting and fasten with screws
(Fig. I, Item 4).
Restore the pump's operational readiness: see section "Replacing the mechanical seal"
[} 200]; steps 5 ... 1!
NOTICE
The electronic module must be pressed on as far as possible when it is installed.
NOTICE
Disconnect the electronic module from the mains supply when performing another
insulation test on site!
To dismantle the module, see section "Replacing the electronic module" and steps
1 ... 5 in the section "Replacing the mechanical seal" [} 200].
Dismantling the fan
1.
Open the cover of the electronic module.
2.
Remove the connection cable of the module fan.
en
205

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yonos giga2.0-d

Table of Contents