P04 Group Space Voltage Vector Control - INVT Goodrive100-PV Series Operation Manual

Solar pump inverter
Hide thumbs Also See for Goodrive100-PV Series:
Table of Contents

Advertisement

Goodrive100-PV Series Solar Pump Inverter
Function
code
Rated current
P02.05
P02.06
resistance of
P02.07
resistance of
Leakage
P02.08
inductance of
Mutual
P02.09
inductance of
Non-load
P02.10
current of AM

P04 group Space voltage vector control

Function
code
V/F curve
P04.00
setting
Name
0.8–6000.0A
of AM
Stator
0.001–65.535Ω After motor parameter
AM
Rotor
0.001–65.535Ω
AM
0.1–6553.5mH
AM
0.1–6553.5mH
AM
0.1–6553.5A
Name
This group of function code defines the V/F
curve of motor 1 to meet the needs of
different loads.
0: Straight-line V/F curve, applicable to
constant torque loads
Description
motor configuration of the
inverter. If the power of the
motor is greatly different
from that of the standard
motor configuration, the
control performance of the
inverter degrades
significantly.
Note: Resetting the rated
power (P02.01) of the
motor can initialize the
parameters P02.02–
P02.10.
autotuning is properly
performed, the values of
P02.06–P02.10
automatically updated.
These parameters are the
benchmark parameters for
high-performance vector
control, directly affecting
the control performance.
Note: Do not modify these
parameters unless it is
necessary.
Description
-27-
Function parameter list
Default Modify
Depend
on
model
Depend
on
model
Depend
on
are
model
Depend
on
model
Depend
on
model
Depend
on
model
Default Modify
4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated

Nedal
May 6, 2025

@Hamse Ismael

Table of Contents

Save PDF