Goodrive100-PV Series Solar Pump Inverter
Function
code
Bus reference
P19.06
Boost voltage
P19.07
Boost voltage
P19.08
Boost software
P19.10
Note:
The duration from when the inverter starts to when it runs at the PI output frequency
lower limit is determined by the ACC time.
Delay time counting follows the rules if multiple fault conditions are met simultaneously:
For example, if all fault conditions of weak light, full water, and underload are met
simultaneously, the delay time for each fault is counted independently. When the delay
time of a fault is reached, the fault is reported. The delay time counting for the other two
faults is kept. If the reported faults is resolved bu the conditions of the other two faults
persist, the delay time counting of the other two faults continues. If a fault condition is not
met during counting, the delay time of this fault is cleared.
Name
This function code is used to set the
reference voltage of bus voltage at PV
input when the system is configured with
the boost module. By default, the factory
voltage
value for 220V models is 350V and the
factory value for 380V models is 570V.
Setting range: 300.0V–600.0V
If
the
reference voltage and actual bus voltage
is greater than 20V, the boost voltage
loop uses PI parameters of this group.
loop KP1
Otherwise, the boost voltage loop uses PI
parameters of the first group.
Setting range: 0.000–65.535
If
the
reference voltage and actual bus voltage
is greater than 20V, the boost voltage
loop uses the PI parameters of this
loop KI1
group. Otherwise, the boost voltage loop
uses the PI parameters of the first group.
Setting range: 0.000–65.535
Once being powered, the boost module
sends its version information to the
version
inverter module.
Description
difference
between
difference
between
-51-
Function parameter list
Default Modify
350.0V
the
bus
0.500
the
bus
0.080
0.00
◎
○
○
●
Need help?
Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?
Questions and answers
I want to connect a low water level sensor to GD100-PV invt how it supposed to do
The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:
1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.
This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.
This answer is automatically generated