P17 Group Status Viewing; P18 Group Status Viewing Functions Special For Solar Inverters - INVT Goodrive100-PV Series Operation Manual

Solar pump inverter
Hide thumbs Also See for Goodrive100-PV Series:
Table of Contents

Advertisement

Goodrive100-PV Series Solar Pump Inverter

P17 group Status viewing

Function
code
Current of the
P17.38
main winding
Current of the
P17.39
secondary

P18 group Status viewing functions special for solar inverters

Function
code
PV reference
P18.00
P18.01
MPPT min.
P18.02
voltage display
P18.04
inductive current
P18.07
PV input power Reserved. Unit: kW
Previous PV
P18.08
input power
Previous PV
P18.09
P18.10
configuration
Name
It is the current of the main winding when
applying capacitance-removing to control
the single phase motor.
0.00–100.00A
It is the current of the secondary winding
when applying capacitance-removing to
control the single phase motor.
winding
0.00–100.00A
Name
MPPT is implemented at the inverter
side. This value is determined at the
voltage
inverter side.
Actual PV
It is transferred from the boost module or
voltage
equal to the bus voltage.
The value displays the mini. voltage
reference during max. power tracking. It
reference
equals the solar cell panel open-circuit
voltage multiplied P15.26.
It is transferred from the boost module.
Present
This function code is valid only in AC
mode and invalid in PV mode.
Reserved. Unit: kW
Reserved. Unit: kW
voltage
0x00–0x11
LED ones:
Device
0: PV power supply
1: AC grid power supply
display
LED tens:
0: Detect that the system is configured
Description
Description
-49-
Function parameter list
Default Modify
0.0A
0.0A
Default Modify

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated

Nedal
May 6, 2025

@Hamse Ismael

Table of Contents

Save PDF