INVT Goodrive100-PV Series Operation Manual page 44

Solar pump inverter
Hide thumbs Also See for Goodrive100-PV Series:
Table of Contents

Advertisement

Goodrive100-PV Series Solar Pump Inverter
Function
code
PI control
P15.03
deviation limit
PID output
P15.04
upper limit
frequency
PID output
P15.05
lower limit
frequency
P15.06
P15.07
P15.08
Name
0.0–100.0% (100.0% corresponds to
P15.02)
PI adjustment is performed only when the
ratio of the difference between the actual
voltage and reference voltage to the
reference voltage, which is abs (Actual
voltage – Reference voltage) * 100.0% /
(Reference voltage), exceeds P15.03. The
default value is 0.0%.
abs: absolute value
P15.05–100.0% (100.0% corresponds to
P00.03)
P15.04
target frequency, and 100.0% corresponds
to P00.03.
After PI adjustment, the target frequency
cannot exceed the upper limit.
0.0%–P15.04
P00.03)
P15.05
target frequency, and 100.0% corresponds
to P00.03.
After PI adjustment, the target frequency
cannot be less than the lower limit.
0.00–100.00
Proportion coefficient 1 of the target
KP1
frequency.
A greater value indicates stronger effect and
faster adjustment.
0.00–100.00
Integral coefficient 1 of target frequency
KI1
A greater value indicates stronger effect and
faster adjustment.
0.00–100.00
Proportion coefficient 2 of target frequency.
KP2
A greater value indicates stronger effect and
faster adjustment.
Description
is used to limit the Max. value of
(100.0%
is used to limit the Min. value of
-40-
Function parameter list
corresponds
to
Default Modify
0.0%
100.0%
20.0%
5.00
5.00
35.00

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated