INVT Goodrive100-PV Series Operation Manual page 52

Solar pump inverter
Hide thumbs Also See for Goodrive100-PV Series:
Table of Contents

Advertisement

Goodrive100-PV Series Solar Pump Inverter
Function
code
Rated pump
P15.35
Rated pump
P15.36
setting at PV
P15.37
undervoltage
P15.39
Name
The pump flow is
flow
runs at the rated frequency and lift. Unit:
cubic meter/hour.
The pump lift is
lift
at the rated frequency and flow. Unit: meter
When the PV voltage is less than the value
of this parameter, the system reports the PV
undervoltage fault.
The factory value depends on the model.
Voltage
point
the boost module
Setting range: 0.0–400.0
This function code is provided for users to
change models. For example, if the user
wants to use model -4 (default after factory
delivery) as model -2,
2.
0: Model -SS2, 220V 1PH input and 1PH
Product
output
model
1: Model -S2, 220V 1PH input and 3PH
output
2: Model -2, 220V 3PH input and 3PH
output
3: Model -4, 380V 3PH input and 3PH
output
Setting range: 0–3
Description
Q N
H
when the pump runs
N
Model
-SS2
-S2
-2
-4
Any model with
P15.39
-48-
Function parameter list
when the pump
PV
undervolta
ge point
140V
140V
140V
240V
70V
shall be set to
Default Modify
0.0
0.0
70.0
0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated

Nedal
May 6, 2025

@Hamse Ismael