P15.09
PI switching
P15.10
Water level
P15.11
selection
Full-water
P15.12
threshold
Name
0.00–100.00
Integral coefficient 2 of the target frequency.
KI2
A greater value indicates stronger effect and
faster adjustment.
0.0–6553.5Vdc
If the absolute value of PV voltage minus
reference value is greater than P15.10,
point
P15.08
P15.06
0: Control through digital input
1: AI1(the water-level signal is input through
AI1, not supported currently)
2: AI2 (the water-level signal is input
through AI2, not supported currently)
3: AI3 (the water-level signal is input
through AI3, not supported currently)
If the function code is 0, the water-level
signal is controlled by the digital input. See
43 and 44 functions of S terminals in group
P05 for detailed information. If the full-water
signal is valid, the system will report the
control
alarm (A-tF) and sleep after the time of
P15.14. During the alarm, the full-water
signal is invalid and the system will clear the
alarm after the time of P15.15. If the
empty-water signal is valid, the system will
report the alarm (A-tL) and sleep after the
time of P15.16. During the alarm, the empty
-water signal is invalid and the system will
clear the alarm after the time of P15.17.
If the function code is 1–3, it is the
reference of water-level control analog
signal. For details, see
0.0–100.0%
This code is valid when
level
control is based on analog input. If the
detected water level control analog signal is
less than the water level threshold
Description
and
P15.09
are used. Otherwise,
and
P15.07
are used.
P15.12
P15.11
-41-
Function parameter list
Default Modify
35.00
20.0V
0
and P12.13.
water level
25.0%
P15.12

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated

Nedal
May 6, 2025

@Hamse Ismael

Subscribe to Our Youtube Channel