Appendix B Recommended Solar Module Configuration; Recommended Solar Module Configuration For Solar Pump Inverters - INVT Goodrive100-PV Series Operation Manual

Solar pump inverter
Hide thumbs Also See for Goodrive100-PV Series:
Table of Contents

Advertisement

Goodrive100-PV Series Solar Pump Inverter

Appendix B Recommended solar module configuration

B.1 Recommended solar module configuration for solar pump inverters
Solar pump inverter model
GD100-0R4G-SS2-PV
GD100-0R7G-SS2-PV
GD100-1R5G-SS2-PV
GD100-2R2G-SS2-PV
GD100-0R4G-S2-PV
GD100-0R7G-S2-PV
GD100-1R5G-S2-PV
GD100-2R2G-S2-PV
GD100-1R5G-2-PV
GD100-2R2G-2-PV
GD100-004G-2-PV
GD100-5R5G-2-PV
GD100-7R5G-2-PV
GD100-0R7G-4-PV
GD100-1R5G-4-PV
GD100-2R2G-4-PV
GD100-004G-4-PV
GD100-5R5G-4-PV
GD100-7R5G-4-PV
GD100-011G-4-PV
GD100-015G-4-PV
GD100-018G-4-PV
GD100-022G-4-PV
GD100-030G-4-PV
GD100-037G-4-PV
GD100-045G-4-PV
GD100-055G-4-PV
GD100-075G-4-PV
Open-circuit voltage class of solar module
37± 1V
Modules per
Module power
± 5Wp
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
-64-
Recommended solar module configuration
Module power
string *
± 5Wp
Strings
11*1
300
11*1
300
11*1
300
11*1
300
11*1
300
11*1
300
11*1
300
11*1
300
11*1
300
11*1
300
11*2
300
11*3
300
11*4
300
18*1
300
18*1
300
18*1
300
20*1
300
18*2
300
18*2
300
18*3
300
18*4
300
18*5
300
18*6
300
18*8
300
18*9
300
18*11
300
18*14
300
18*19
300
45± 1V
Modules per
string *
Strings
9*1
9*1
9*1
9*1
9*1
9*1
9*1
9*1
9*1
9*1
9*2
9*3
9*4
15*1
15*1
15*1
16*1
15*2
15*2
15*3
15*4
15*5
15*6
15*8
15*9
15*11
15*14
15*19

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated

Nedal
May 6, 2025

@Hamse Ismael

Table of Contents

Save PDF