Goodrive100-PV Series Solar Pump Inverter
Function
code
P00.11
ACC time 1
P00.12
DEC time 1
Running
P00.13
direction
Name
frequency if the set frequency is lower than
the lower limit.
Note: Max. output frequency ≥ Upper limit
frequency ≥ Lower limit frequency
Setting range:
of running frequency)
ACC time means the time needed if the
inverter speeds up from 0Hz to the Max.
output frequency (P00.03).
DEC time means the time needed if the
inverter speeds down from the Max. output
frequency to 0Hz (P00.03).
The inverter has four groups of ACC/DEC
time which can be selected by P05. The
factory default ACC/DEC time of the
inverter is the first group.
Setting range of
3600.0s
0: Run at the default direction. The inverter
runs in the forward direction. FWD/REV
indicator is off.
1: Run at the opposite direction. The
inverter runs in the reverse direction.
FWD/REV indicator is on.
Modify P00.13 to shift the rotation direction
of the motor. This effect equals to the
shifting the rotation direction by adjusting
either two of the motor lines (U, V and W).
The motor rotation direction can
changed by QUICK/JOG on the keypad.
Refer to parameter P07.02.
Note:
When the parameter is restored to the
default value, the motor's running direction
is restored to the default one. Exercise
caution before using this function if the
change of motor rotation direction is
disallowed after commissioning.
Description
0.00Hz–P00.04
(Upper limit
P00.11
and P00.12: 0.0–
-24-
Function parameter list
Default Modify
Depend
○
on mode
Depend
○
on mode
○
0
be
Need help?
Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?
Questions and answers
I want to connect a low water level sensor to GD100-PV invt how it supposed to do
The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:
1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.
This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.