Goodrive100-PV Series Solar Pump Inverter

P08 group Enhanced functions

Function
code
Auto fault reset
P08.28
Auto fault reset
P08.29

6.2 Function parameters special for solar pump

P11 group Protection parameters

Function
Name
code
Protection
P11.00
against phase
Frequency
decrease at
P11.01
sudden power
Frequency
decrease ratio
P11.02
at sudden
power loss
Name
0–10
count
0.1–3600.0s
interval
0x000–0x011
LED ones:
0: Software protection against input phase
loss disabled
1: Software protection against input phase
loss enabled
LED tens:
0: Software protection against output phase
loss
loss disabled
1: Software protection against output phase
loss enabled
LED hundreds:
Reserved
000–111
0: Disable
1: Enable
loss
Setting range: 0.00Hz–P00.03/s
If the bus voltage drops to the sudden
frequency decreasing point due to the
power loss of the grid, the inverter begins to
decrease the running frequency according
to
P11.02
generation state. The regenerative power
Description
Description
to make the motor in power
-38-
Function parameter list
Default Modify
5
10.0s
Default Modify
Depend
on
model
0
0.00Hz/
s

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.