r0721
CU digital inputs, terminal actual value / CU DI actual value
CU240B-2
Access level: 2
CU240B-2 DP
Can be changed: -
Units group: -
Min
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the simu-
lation mode (p0795.x = 1) to terminal mode (p0795.x = 0).
Bit field:
Bit
Signal name
00
DI 0 (T. 5)
01
DI 1 (T. 6)
02
DI 2 (T. 7)
03
DI 3 (T. 8)
11
DI 11 (T. 3, 4) AI 0
Note:
DI: Digital Input
T: Terminal
r0721
CU digital inputs, terminal actual value / CU DI actual value
CU240E-2
Access level: 2
CU240E-2 DP
Can be changed: -
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the simu-
lation mode (p0795.x = 1) to terminal mode (p0795.x = 0).
Bit field:
Bit
Signal name
00
DI 0 (T. 5)
01
DI 1 (T. 6)
02
DI 2 (T. 7)
03
DI 3 (T. 8)
04
DI 4 (T. 16)
05
DI 5 (T. 17)
11
DI 11 (T. 3, 4) AI 0
12
DI 12 (T. 10, 11) AI 1
Note:
DI: Digital Input
T: Terminal
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
High
High
High
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
High
High
High
High
High
High
Parameters
List of Parameters
Data type: Unsigned32
Data set: -
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Data type: Unsigned32
Data set: -
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
FP
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
1-91