r0334[0...n]
Actual motor-torque constant / Mot kT act
Access level: 4
Can be changed: -
Units group: 28_1
Min
- [Nm/A]
Description:
Displays the torque constant of the synchronous motor used.
Dependency:
IEC drives (p0100 = 0): unit Nm / A
NEMA drives (p0100 = 1): unit lbf ft / A
Note:
This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 is calculated from p0305, p0307 and p0311.
p0335[0...n]
Motor cooling type / Motor cooling type
Access level: 2
Can be changed: C(1, 3), T
Units group: -
Min
0
Description:
Sets the motor cooling system used.
Value:
0:
1:
2:
128:
Dependency:
For 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
The parameter influences the thermal 3-mass motor model.
1LA7 motors, frame size 56 are operated without fan.
r0337[0...n]
Rated motor EMF / Mot EMF_rated
Access level: 4
Can be changed: -
Units group: -
Min
- [Vrms]
Description:
Displays the rated EMF of the motor.
Note:
EMF: Electromagnetic force
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Non-ventilated
Forced cooling
Liquid cooling
No fan
Calculated: -
Scaling: -
Unit selection: p0100
Max
- [Nm/A]
Calculated: -
Scaling: -
Unit selection: -
Max
128
Calculated: -
Scaling: -
Unit selection: -
Max
- [Vrms]
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: MDS
Factory setting
- [Nm/A]
Data type: Integer16
Data set: MDS
Factory setting
0
Data type: FloatingPoint32
Data set: MDS
Factory setting
- [Vrms]
1-61