Siemens CU240B-2 Parameter Manual page 106

Table of Contents

Advertisement

Parameters
List of Parameters
p0803
Data transfer: device memory as source/target / Dev_mem src/targ
Access level: 3
Can be changed: T
Units group: -
Min
0
Description:
Sets the number for data transfer of a parameter backup from/to device memory.
Transfer from memory card to device memory (p0804 = 1):
- Sets the target of the parameter backup (e.g. p0803 = 10 --> PS010xxx.ACX is the target).
Transfer from non-volatile device memory to memory card (p0804 = 2):
- Sets the source of the parameter backup (e.g. p0803 = 11 --> PS011xxx.ACX is the source).
Value:
0:
10:
11:
12:
Dependency:
Refer to: p0802, p0804
Notice:
If the data between the volatile and non-volatile device memories differ, then it may be necessary to save the data
on the memory card in a non-volatile fashion prior to the transfer (e.g. p0971 = 1).
1-106
Source/target standard
Source/target with setting 10
Source/target with setting 11
Source/target with setting 12
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
12
Data type: Integer16
Data set: -
Factory setting
0
© Siemens AG 2011 All Rights Reserved