Parameters
List of Parameters
p1500[0...n]
Torque setpoint selection / M_set sel
CU240E-2
Access level: 2
CU240E-2 F
Can be changed: C(1), T
Units group: -
Min
0
Description:
Sets the source for the torque setpoint.
For single-digit values, the following applies:
The value specifies the main setpoint.
For double-digit values, the following applies:
The left-hand digit specifies the supplementary setpoint, the right-hand digit the main setpoint.
Example:
Value = 26
--> The analog setpoint (2) supplies the supplementary setpoint.
--> The fieldbus (6) supplies the main setpoint.
Value:
0:
2:
6:
7:
20:
22:
26:
27:
60:
62:
66:
67:
70:
72:
76:
77:
Dependency:
When changing this parameter, the following settings are influenced:
Refer to: p1503, p1511
Caution:
When executing a specific macro, the corresponding programmed settings are made and become active.
1-208
No main setpoint
Analog setpoint
Fieldbus
Analog setpoint 2
Analog setpoint + no main setpoint
Analog setpoint + analog setpoint
Analog setpoint + fieldbus
Analog setpoint + analog setpoint 2
Fieldbus + no main setpoint
Fieldbus + analog setpoint
Fieldbus+fieldbus
Fieldbus + analog setpoint 2
Analog setpoint 2 + no main setpoint
Analog setpoint 2 + analog setpoint
Analog setpoint 2 + fieldbus
Analog setpoint 2 + analog setpoint 2
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
77
Data type: Integer16
Data set: CDS, p0170
Factory setting
2