Siemens CU240B-2 Parameter Manual page 100

Table of Contents

Advertisement

Parameters
List of Parameters
p0773[0...1]
CU analog outputs smoothing time constant / CU AO T_smooth
Access level: 2
Can be changed: U, T
Units group: -
Min
0.0 [ms]
Description:
Sets the smoothing time constant of the 1st-order low pass filter for the analog outputs.
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Note:
AO: Analog Output
T: Terminal
r0774[0...1]
CU analog outputs output voltage/current actual / CU AO U/I_outp
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Displays the actual output voltage or output current at the analog outputs.
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Dependency:
Refer to: p0776
Note:
AO: Analog Output
T: Terminal
p0775[0...1]
CU analog outputs activate absolute value generation / CU AO absVal act
Access level: 2
Can be changed: T
Units group: -
Min
0
Description:
Activates the absolute value generation for the analog outputs.
Value:
0:
1:
Index:
[0] = AO0 (T 12/13)
[1] = AO1 (T 26/27)
Note:
AO: Analog Output
T: Terminal
1-100
No absolute value generation
Absolute value generation switched in
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
1000.0 [ms]
Calculated: -
Scaling: p2001
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
1
Data type: FloatingPoint32
Data set: -
Factory setting
0.0 [ms]
Data type: FloatingPoint32
Data set: -
Factory setting
-
Data type: Integer16
Data set: -
Factory setting
0
© Siemens AG 2011 All Rights Reserved