Siemens CU240B-2 Parameter Manual page 641

Table of Contents

Advertisement

0.00 ... 10000.00 [Aeff]
I_act abs val [Aeff]
r0068
[0]
not smoothed
<1>
Mot temp [°C]
[8016.5]
r0035
<1>
Only if there is a temperature sensor (p0601 = 2).
Only if <1> are not met.
<2>
1
2
Signals and monitoring functions
Thermal I²t motor model (PEM, p0300 = 2xx)
Therm Mot_mod conf
- ... -
p0612 [D] (0010 bin)
Mot I_standstill
p0318 [D] (0.00)
Thermal
I²t motor model
(only for synchronous
machine)
I2t mot_mod T
0 ... 20000 [s]
p0611 [D] (0)
Mot T_ambient
-40 ... 80 [°C]
p0625 [D] (20)
<2>
3
4
I2t mot_mod thresh
0.0 ... 220.0 [°C]
p0615 [D] (180.0)
1
0
model
– 40 K
model
x 100 [%]
p0605 – 40 K
Mot_temp flt thr
0.0 ... 240.0 [°C]
p0605 [D] (145.0)
1
0
5
6
FP_8017_97_51.vsd
13.12.2010
V4.4
[8016.6]
Motor utilization [%]
r0034
A07012
"I²t-motor model overtemperature"
7
8
Function diagram
- 8017 -
G120 CU240B/E-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f

Table of Contents