Siemens CU240B-2 Parameter Manual page 204

Table of Contents

Advertisement

Parameters
List of Parameters
p1479[0...n]
CI: Speed controller integrator setting value scaling / n_ctrl I_val scal
Access level: 4
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the integrator setting value (p1478) of the speed controller.
Dependency:
Refer to: p1477, p1478
r1482
CO: Speed controller I torque output / n_ctrl I-M_output
Access level: 3
Can be changed: -
Units group: 7_1
Min
- [Nm]
Description:
Displays the torque setpoint at the output of the I speed controller.
p1486[0...n]
CI: Droop compensation torque / Droop M_comp
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the compensation torque to be output within the droop calculation.
p1487[0...n]
Droop compensation torque scaling / Droop M_comp scal
Access level: 3
Can be changed: U, T
Units group: -
Min
-2000.0 [%]
Description:
Sets the scaling for the compensation torque within the droop calculation.
p1488[0...n]
Droop input source / Droop input source
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Sets the source for droop feedback.
Value:
0:
1:
2:
3:
Dependency:
Refer to: p1489, r1490, p1492
1-204
Droop feedback not connected
Droop from torque setpoint
Droop from speed controller output
Droop from integral output, speed controller
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
2000.0 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
3
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
1
Data type: FloatingPoint32
Data set: -
Factory setting
- [Nm]
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
0
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
100.0 [%]
Data type: Integer16
Data set: DDS, p0180
Factory setting
0