r9723.0...16
CO/BO: SI Motion diagnostic signals integrated in the drive / SI Mtn integ diag
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
-
Description:
Displays the diagnostic signals for safety-relevant motion monitoring functions integrated in the drive.
Bit field:
Bit
Signal name
00
Forced checking procedure required
01
For ESR, STOP F and subsequent stop B is
active
02
Communication failure
03
Actual value sensing supplies valid value
04
Encoderless act val sensing acc to tech-
nique for U/f control
16
SAM/SBR active
Note:
ESR: Extended Stop and Retract
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
r9724
SI Motion crosswise comparison clock cycle / SI Mtn CDC clk cyc
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
- [ms]
Description:
Displays the crosswise comparison clock cycle.
The value indicates the clock cycle time with which each individual CDC value is compared between the two moni-
toring channels.
Note:
CDC: Crosswise Data Check
r9725[0...2]
SI Motion, diagnostics STOP F / SI Mtn Diag STOP F
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
-
Description:
Re index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
Processor 1 signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
Re index 1:
Displays the value from processor 1 that resulted in the STOP F.
Re index 2:
Displays the value from processor 2 that resulted in the STOP F.
Index:
[0] = Message value for CDC
[1] = Processor 1 CDC actual value
[2] = Processor 2 CDC actual value
Dependency:
Refer to: C01711
Note:
The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Check
1-366
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
- [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
-
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: Unsigned32
Data set: -
Factory setting
-
0 signal
No
No
No
No
No
No
Data type: FloatingPoint32
Data set: -
Factory setting
- [ms]
Data type: Unsigned32
Data set: -
Factory setting
-
© Siemens AG 2011 All Rights Reserved
FP
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f

Table of Contents