Parameters
List of Parameters
p9700
SI copy function / SI copy function
CU240E-2
Access level: 3
CU240E-2 DP
Can be changed: C(95), U, T
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
0000 hex
Description:
Setting to start the required copy function.
After starting, the corresponding parameters are copied from processor 1 to processor 2.
Once copying is complete, the parameter is automatically reset to zero.
Value:
0:
29:
87:
208:
Dependency:
Refer to: r3996
Notice:
When the parameters are copied, short-term communication interruptions may occur.
Note:
Re value = 57 hex and D0 hex:
The value can only be set if the safety commissioning mode is set and the Safety Integrated password was entered.
Re value = D0 hex:
The following parameters are copied after starting the copy function:
p9601 --> p9801, p9610 --> 9810, p9650 --> p9850, p9651 --> p9851
p9701
Acknowledge SI data change / Ackn SI data
CU240E-2
Access level: 3
CU240E-2 DP
Can be changed: C(95), U, T
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
0000 hex
Description:
Setting to transfer the reference checksums from the associated actual checksums after changes (SI parameters,
hardware).
After transferring the reference checksums, parameters are automatically reset to zero.
Value:
0:
172:
220:
236:
Dependency:
Refer to: r9398, p9399, r9728, p9729, r9798, p9799, r9898, p9899
Note:
Re value = AC and DC hex:
These values can only be set if the safety commissioning mode is set and the Safety Integrated password was
entered.
p9705
BI: SI Motion: Test stop signal source / SI Mtn test stop
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
-
Description:
Sets the signal source for the test stop of the safety-relevant motion monitoring functions.
1-362
[00 hex] Copy function ended
[1D hex] Start copy function node identifier
[57 hex] Start copy function SI parameters
[D0 hex] Start copy function SI basic parameters
[00 hex] Data unchanged
[AC hex] Acknowledge data change complete
[DC hex] Acknowledge SI basic parameter change
[EC hex] Acknowledge hardware CRC
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
00D0 hex
Calculated: -
Scaling: -
Unit selection: -
Max
00EC hex
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Integer16
Data set: -
Factory setting
0000 hex
Data type: Integer16
Data set: -
Factory setting
0000 hex
Data type: U32 / Binary
Data set: -
Factory setting
0