290
Gateway and Gateway 4 Manual v1.2
28
Gateway 4 Specifications
Input/Output
Specifications
RJ45 Analog Inputs 1-
4/AES3 Inputs 1-4
RJ45 Analog Outputs
1-4/AES3 Outputs 1-4
Gigabit LAN Ports
Gigabit AoIP
Streaming Ports
USB 2.0 Host Port
USB 3.0 Host Port
Front Panel
Headphone Output
Front Panel SD Card
Slot
BNC Sync
Input/Output
Control Port In/Out
Analog Input
Impedance
Analog Output
Impedance
Clipping Level
A/D & D/A Converters 24 bit
AES3 (AES/EBU)
Frequency Response 20Hz to 22kHz
Total Harmonic
Distortion
Signal to Noise Ratio >100dB at +24dBu, unweighted, 20Hz – 20kHz
Crosstalk
Data and Control
Configuration
connectivity
Web
Monitoring
Serial (DB-9)
Software Logic I/Os
(SLIO)
Encoding
Streaming
Shared analog stereo line inputs 1-4, or stereo AES3 digital inputs 1-4
Shared analog stereo line outputs 1-4, or stereo AES3 digital outputs 1-4
2 x Gbit Ethernet ports for IP streaming over WANs (4 mono, stereo and dual
mono, or 2 stereo - full duplex)
2 x Gbit Ethernet ports for AES67 or Optional WheatNet-IP streaming over
LAN 1 (4 bidirectional mono or 2 bidirectional stereo); port 2 not operational
in early releases
Front panel host port (supports firmware upgrades, Wi-Fi USB modems and
memory sticks)
Rear panel host port supports record and playback*
1 x 6.35mm (1/4") headphone Jack
Full size push-push SD card slot for backup/restore config, firmware
upgrades, file storage, and SDIO capability*
2 configurable input/output BNC sync connectors
Dual DB-25 Control Ports support 8 CMOS control inputs and 8 opto-isolated
solid-state relay outputs
> 10kW
< 30 ohm balanced
Nominal output level +4dBu with maximum output + 24 dBu
24 bit inputs with support for sample rates from 32kHz to 192 kHz*; 24 bit
outputs
<0.002% at +22dBu unweighted
< -95dB between adjacent channels
and
HTML5 Toolbox Web-GUI, Cloud Codec Controller (CCC), TieLink Traversal
Server*
Audio
Selectable web audio monitoring of IP audio streams
RS232 up to 115kbps with or without CTS/RTS flow control can be used as
a proprietary data channel
8 hardware GPIOs, plus 3 virtual inputs, 56 logical outputs, and 64
WheatNet Logic Inputs/Outputs
and
IP
© Tieline Research Pty. Ltd. 2021