Codec Tieline Gateway User Manual page 208

Table of Contents

Advertisement

208
Gateway and Gateway 4 Manual v1.2
2. Click to select an alarm from the list on the left side of the panel.
3. Click Edit to configure alarm settings.
4. Click the Enabled check-box to activate the alarm and then select an Alarm Severity level
from the drop-down menu.
5. Click Save to store the new settings.
Note: The following System and Audio alarms are available:
Alarm
PSU Failure
Input Silence
Connection Lost
Temperature
AES Reference Lost
AES Input Lost
Program Failure
Scheduled Event Failed
Alarm
Explanation
Type
System
Raises an alarm if one or both PSUs fail
Audio
Raises an alarm if input audio is lost based on whether
silence is detected on a single input, or pair of inputs
(according to preconfigured silence detection threshold
parameters)
Audio
Triggers and alarm whenever a streaming connection is
lost
System
Raises an alarm if the temperature is too low or too high
Audio
Raises an alarm if the AES reference clock signal is lost
(not available in WheatNet-IP capable codecs)
Audio
Raises an alarm if the AES input signal is lost (not
available in WheatNet-IP capable codecs)
Audio
An element within a configured program has failed and
has not been terminated manually. Note: the alarm is
cleared if the program is unloaded.
Audio
A scheduled event could not be started or stopped at the
specified time. Note: the alarm is only present for the
duration of the event.
© Tieline Research Pty. Ltd. 2021

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tieline Gateway and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Tieline gateway-4

Table of Contents