Disc o nne c ting the Po we r
The power input connectors can be disconnected from the power source individually.
1
Disconnect the power cord from the power outlet.
2
Disconnect the power cord from the AC power socket.
3.3 L EDs
The following table describes the LEDs.
Table 4 LEDs
L ED
PWR1
PWR2
SYS (System)
Chapter 3 Hardware Panels
C O L O R
ST AT US
DESC RIPT IO N
Green
On
The Switch is receiving power from the power module in the first power
slot.
Blinking
The Switch is returning to the last-saved custom default configuration
settings.
Amber
On
The Switch is returning to its factory default configuration settings.
Blinking
The
•
•
Off
The Switch is not receiving power from the power module in the first
power slot.
Green
On
The Switch is receiving power from the power module in the second
power slot.
Blinking
The Switch is returning to the last-saved custom default configuration
settings.
Amber
On
The Switch is returning to its factory default configuration settings.
Blinking
The
•
•
Off
The Switch is not receiving power from the power module in the second
power slot.
Green
On
The Switch is on and functioning properly.
Blinking
The Switch is rebooting and performing self-diagnostic tests.
Red
On
The Switch is functioning abnormally.
Off
The power is off or the system is not ready or malfunctioning.
XS3800-28 User's Guide
LED will blink in amber in the following situations:
PWR1
The Switch detected a power supply failure with the power cable
connected to the Switch and a power source.
The fans are not functioning at a proper speed or malfunctioning.
LED will blink in amber in the following situations:
PWR2
The Switch detected a power supply failure with the power cable
connected to the Switch and a power source.
The fans are not functioning at a proper speed or malfunctioning.