Leds - ZyXEL Communications XS1930-12F User Manual

10/12-port multi-gigabit/sfp+ smart managed l2 switch 12-port multi-gigabit smart managed poe switch
Table of Contents

Advertisement

3.3 LEDs

After you connect the power to the Switch, view the LEDs to ensure proper functioning of the Switch
and as an aid in troubleshooting.
Table 6 LED Descriptions
LED
PWR
SYS
CLOUD
LOCATOR
PoE MAX
(XS1930-12HP)
Bar1 is the bar at
the bottom; bar
5 is the bar at
the top.
10GBase-T Ports
Chapter 3 Hardware Panels
COLOR
STATUS
Green
On
Blinking
Amber
On
Off
Green
On
Blinking
Red
On
Off
Green
On
Blinking
Amber
On
Blinking
Off
Blue
On
Blinking
Off
Green
On
(Bar1 – Bar3)
Yellow
On
(Bar4)
Red
On
(Bar5)
Blinking
Off
XS1930 Series User's Guide
DESCRIPTION
The Switch is receiving power from the power source.
The Switch is returning to the custom default configuration
settings.
The Switch is returning to its factory default configuration
settings.
The Switch is not receiving power from the power source.
The Switch is on and functioning properly.
The Switch is rebooting and performing self-diagnostic tests.
The Switch is functioning abnormally.
The power is off or the Switch is not ready/malfunctioning.
The Switch is managed by the NCC (Nebula Control Center).
The Switch is connected to the NCC, but not registered.
The Switch is in Nebula cloud management mode. It was trying
to connect to the NCC, but failed.
The Switch is in standalone mode. It was trying to connect to
the NCC, but failed.
Nebula cloud management mode is disabled.
The Switch is uploading firmware. While the Switch is doing this,
do not turn off the power.
Shows the actual location of the Switch between several
devices in a rack. The default timer is 30 minutes when you are
configuring the Switch.
The locator is not functioning or malfunctioning.
Each bar represents 20% of PoE Power consumption.
Bar 1: PoE power usage is below 20 percent of the power
supplied budget.
Bar 2: PoE power usage is below 40 percent of the power
supplied budget, but over 20 percent of the power supplied
budget.
Bar 3: PoE power usage is below 60 percent of the power
supplied budget, but over 40 percent of the power supplied
budget.
PoE power usage is below 80 percent of the power supplied
budget, but over 60 percent of the power supplied budget.
PoE power usage is more than 80 percent of the power
supplied budget.
Less than 5 percent of the power supplied budget remains. 5
percent is the default value.
PoE power usage is 0 percent of the power supplied budget.
40