14. OPTIONS AND AUXILIARY EQUIPMENT
14.11 Power factor improving DC reactor
The power factor improving DC reactor increases the form factor of the servo amplifier's input current to
improve the power factor. It can decrease the power supply capacity. As compared to the power factor
improving AC reactor (FR-BAL), it can decrease the loss. The input power factor is improved to about 95%.
It is also effective to reduce the input side harmonics.
When connecting the power factor improving DC reactor to the servo amplifier, always disconnect P
(For 11kW or more, disconnect P
reactor is not produced.
When used, the power factor improving DC reactor generates heat. To release heat, therefore, leave a 10cm or
more clearance at each of the top and bottom, and a 5cm or more clearance on each side.
Rating plate
Terminal box - screw size G
E
A or less
2-F
L notch
Note 1. Since the terminal cover is supplied, attach it after connecting a wire.
2. When using DC reactor, disconnect P
3. When over 11kW, "P
POINT
For the 100V power supply type (MR-J3- T1), the power factor improving DC
reactor cannot be used.
and P). If it remains connected, the effect of the power factor improving DC
1
Servo amplifier
FR-BEL-(H)
P
(Note 2)
P
5m or less
H
B or less
Mounting leg
F
Fig. 14.2
and P
.
1
2
" becomes "P" respectively.
2
Rating plate
Screw size G
1
2
E
A or less
2-F
14 - 69
(Note 1)Terminal cover
FR-BEL-(H)
H
B or less
L notch
Mounting leg
F
Fig. 14.3
and P
1
2
[Unit: mm]
Servo amplifier
P
1
(Note 3)
(Note 2)
P
2
5m or less