3. CC-LINK COMMUNICATION FUNCTIONS
3.2.4 Communication baud rate setting
Set the transfer baud rate of CC-Link with the transfer baud rate switch (MODE) on the servo amplifier front.
The initial value is set to 156kbps.
The overall distance of the system changes with the transfer speed setting. For details, refer to the CC-Link
system master/local unit user's manual.
Servo amplifier
5
3.2.5 Occupied station count setting
Set the number of occupied stations with the occupied station count switch (SW1) on the servo amplifier front.
The usable I/O device and the number of connectable units change with the set number of occupied stations.
Refer to section 3.2.3. In the initial status, the number of stations occupied is set to 1.
Servo amplifier
(Note)
Note.
SW1
5
5
5
5
5
This switch hidden under the cover is for manufacturer setting.
Do not change this setting by any means.
MODE
5
0 (initial value)
5 to 9
SW1 setting
Initial value
3 - 6
No.
Baud rate
156kbps
1
625kbps
2
2.5Mbps
3
5Mbps
4
10Mbps
Not used
Number of occupied stations
1 station occupied
2 station occupied