Mitsubishi Electric MELSERVO-J3 Series Manual page 448

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

14. OPTIONS AND AUXILIARY EQUIPMENT
(a) When using the 600V Polyvinyl chloride insulated wire (IV wire)
Selection example of wire size when using IV wires is indicated below.
Servo amplifier
1)
L
L
1
2
MR-J3-10T(1)
MR-J3-20T(1)
MR-J3-40T(1)
MR-J3-60T
2(AWG14)
MR-J3-70T
MR-J3-100T
MR-J3-200T
MR-J3-350T
3.5(AWG12)
MR-J3-500T
5.5(AWG10): a
(Note 2)
MR-J3-700T
8(AWG8): b
(Note 2)
MR-J3-11KT
14(AWG6): c
(Note 2)
MR-J3-15KT
22(AWG4): d
(Note 2)
MR-J3-22KT
50(AWG1/0):
(Note 2)
f
MR-J3-60T4
MR-J3-100T4
2(AWG14)
MR-J3-200T4
MR-J3-350T4
2(AWG14): g
MR-J3-500T4
(Note 2)
5.5(AWG10): a
MR-J3-700T4
(Note 2)
MR-J3-11KT4
8(AWG8): l
(Note 2)
MR-J3-15KT4
14(AWG6): c
(Note 2)
MR-J3-22KT4
14(AWG6): m
(Note 2)
Note 1. Alphabets in the table indicate crimping tools. For crimping terminals and applicable tools, refer to (1) (c) in this section.
2. When connecting to the terminal block, be sure to use the screws which are provided with the terminal block.
3. For the servo motor with a cooling fan.
4. Wires are selected based on the highest rated current among combining servo motors.
Use wires 8) of the following sizes with the power regeneration converter (FR-RC-(H)).
Model
FR-RC-15K
FR-RC-30K
FR-RC-55K
FR-RC-H15K
FR-RC-H30K
FR-RC-H55K
Table 14.1 Wire size selection example 1 (IV wire)
2) L
L
11
21
L
U V W
3
1.25(AWG16)
1.25(AWG16)
2(AWG14)
3.5(AWG12)
5.5(AWG10): a 2(AWG14): g
1.25(AWG16):
h
8(AWG8): b
22(AWG4): d
1.25(AWG16):
30(AWG2): e
g
60(AWG2/0): f 5.5(AWG10): k
1.25(AWG16)
1.25(AWG16)
2(AWG14)
2(AWG14): g
1.25(AWG16):
h
5.5(AWG10): a
8(AWG8): l
1.25(AWG16):
22(AWG4): d
g
22(AWG4): n
2
Wires[mm
]
14(AWG6)
14(AWG6)
22(AWG4)
14(AWG6)
14(AWG6)
14(AWG6)
2
Wires [mm
] (Note 1, 4)
3)
4) P C
2(AWG14)
3.5(AWG12): a
5.5(AWG10): j
1.25(AWG16)
2(AWG14)
2(AWG14): g
3.5(AWG12): j
5.5(AWG10): j
5.5(AWG10): k
14 - 63
6)
5) B1 B2
BU BV BW
2(AWG14)
(Note 3)
2(AWG14)
2(AWG14)
(Note 3)
2(AWG14)
7)
OHS1 OHS2
1.25(AWG16)
(Note 3)
1.25(AWG16)
1.25(AWG16)
(Note 3)
1.25(AWG16)

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents