Mitsubishi Electric MELSERVO-J3 Series Manual page 641

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

APPENDIX
App. 5.3 CNP1, CNP2, CNP3 wiring method (4.3.3 CNP1, CNP2, CNP3 wiring method)
(a) Servo amplifier power supply connectors
Servo amplifier power supply connectors
<Applicable cable example>
Cable finish OD: to
5mm
<Applicable cable example>
Cable finish OD: to
3.8mm
(b) Termination of the cables
1) CNP1 CNP3
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid
a short caused by the loose wires of the core and the adjacent pole. Do not solder the core as
it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
2
[mm
]
AWG
1.25/1.5
16
2.0/2.5
14
3.5
12
2) CNP2
CNP2 is the same as MR-J3-100T or smaller capacities. Refer to section 4.3.3 (1) (b).
Connector for CNP1
PC4/6-STF-7.62-CRWH
(Phoenix Contact)
Connector for CNP3
PC4/3-STF-7.62-CRWH
(Phoenix Contact)
Connector for CNP2
54928-0520 (Molex)
Bar terminal type
For 1 cable
AI1.5-8BK
AI-TWIN2 1.5-8BK
AI2.5-8BU
AI-TWIN2 2.5-10BU
AI4-10Y
Servo amplifier
CNP1
CNP3
CNP2
Sheath
Core
7mm
For 2 cables
CRIMPFOX-ZA3
App. - 8
Crimping tool
Manufacturer
Phoenix Contact

Advertisement