16. INDEXER POSITIONING OPERATION
(2) Parameter write inhibit
No.
Symbol
PA19
*BLK
Parameter write inhibit
In the factory setting, this servo amplifier allows changes to the basic setting parameter, gain/filter
parameter and extension setting parameter settings. With the setting of parameter No.PA19, write can be
disabled to prevent accidental changes.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No.PA19. Operation can be performed for the parameters marked
Parameter No.PA19
setting
0000h
000Bh
000Ch
(initial value)
100Bh
100Ch
(3) Selection of command system
No.
Symbol
PA01
*STY
Control mode
Select the command system.
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after
setting.
Basic setting
Setting operation
parameters
No.PA
Reference
Write
Reference
Write
Reference
Write
Reference
Parameter No.
Write
PA19 only
Reference
Parameter No.
Write
PA19 only
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after
setting.
Parameter No.PA01
0 0
0
Gain/Filter
parameters
No.PB
Operation method
0: Point table positioning operation
1: Indexer positioning operation
16 - 71
Initial
Unit
Setting range
value
000Ch
Refer to the text.
.
Extension setting
I/O setting
parameters
parameters
No.PC
No.PD
Initial
Unit
Setting range
value
0000h
Refer to the text.