Mitsubishi Electric MELSERVO-J3 Series Manual page 590

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

16. INDEXER POSITIONING OPERATION
(a) For MR-J3-350T or less MR-J3-200T4 or less
(b) For MR-J3-500T or more MR-J3-350T4 or more
(c) Parameter setting
Set parameter No.PA03 (Absolute position detection system) as indicated below to make the absolute
position detection system valid.
POINT
For the servo amplifier with a battery holder on the bottom, it is not possible to
wire for the earth with the battery installed. Insert the battery after executing
the earth wiring of the servo amplifier.
Parameter No.PA03
1
Selection of absolute position detection system
0: Incremental system
1: Absolute position detection system
Insert connector into CN4.
Insert connector into CN4.
16 - 69