16. INDEXER POSITIONING OPERATION
(2) Detail list
No.
Symbol
PB01
FILT
Adaptive tuning mode (Adaptive filter )
Select the setting method for filter tuning. Setting this parameter to "
(filter tuning mode 1) automatically changes the machine resonance
suppression filter 1 (parameter No.PB13) and notch shape selection (parameter
No.PB14).
Setting
Note. Parameter No.PB13 and PB14 are fixed to the initial values.
When this parameter is set to "
positioning is done the predetermined number or times for the predetermined
period of time, and the setting changes to "
not necessary, the setting changes to "
"
0", the initial values are set to the machine resonance suppression filter
1 and notch shape selection. However, this does not occur when the servo off.
Name and function
Machine resonance point
Notch frequency
0 0 0
Filter tuning mode selection
Filter adjustment mode
0
Filter OFF
1
Filter tuning mode
2
Manual mode
1", the tuning is completed after
Frequency
Frequency
Automatically set parameter
(Note)
Parameter No.PB13
Parameter No.PB14
2". When the filter tuning is
0". When this parameter is set to
16 - 80
Initial value
Unit
0000h
1"
Setting
range