Power Factor Improving Dc Reactors - Mitsubishi Electric MELSERVO-J2-Super Series Supplementary Instructions Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

6. OPTIONS AND AUXILIARY EQUIPMENT

6.2.4 Power factor improving DC reactors

The input power factor is improved to be about 95%.
Name plate
Power factor
Servo amplifier
improving DC
reactors
MR-J2S-11KA
FR-BEL-H15K
MR-J2S-15KA
FR-BEL-H22K
MR-J2S-22KA
FR-BEL-H30K
(Note 1) Terminal cover
Screw size G
E
A or less
5m or less
FR-BEL
(Note2)
Note 1. Fit the supplied terminal cover after wiring.
2. When using the DC reactor, remove the short-circuit bar across P
Dimensions [mm (in) ]
A
B
C
D
170
93
160
2.3
(6.69)
(3.66)
(6.29)
(0.09)
185
119
171
2.6
(7.28)
(4.69)
(6.73)
(0.10)
185
119
189
2.6
(7.28)
(4.69)
(7.44)
(0.10)
2-F L
Notch
B or less
F
Servo amplifier
P
P
1
E
F
L
155
6
14
(6.10)
(0.24)
(0.55)
(0.24)
165
7
15
(6.49)
(0.28)
(0.59)
(0.24)
165
7
15
(6.49)
(0.28)
(0.59)
(0.24)
6 - 29
H
Mounting foot part
-P.
1
Terminal
Mass
screw size
[kg (lb)]
G
H
6
56
3.7
M5
(2.21)
(8.16)
6
70
5.0
M6
(2.76)
(11.0)
6
70
6.7
M6
(2.76)
(14.8)
Used wire
2
[mm
]
8(AWG8)
22(AWG4)

Advertisement

Table of Contents
loading

Table of Contents